A toggle switch and rotary switch function on P1 board
Toggle Switches
FWR allows flash writes
TOP top call
BOT lower call
UPC elevator car rises
DNC lift car lift
R / M allows remote alarm
IND independent (LEHY-C with energy feedback)
DRSW Door Shutdown Machine (Another code is DOOR)
RST elevator reset
DCB closed
FMS write layer height data (LEHY-C with energy feedback and LEHY-2 non-energy feedback)
SW1 up / SW1 down LD0 / LD1 and up call and down call (LEHY-C with energy feedback)
SW2 top / SW2 top call and bottom call (LEHY-C with energy feedback)
Top call and bottom call under TCA / TCA (LEHY-2 non-energy feedback)
MCA Up / MCA Up Call and Down Call? (LEHY-2 non-energy feedback)
LD0 / LD1 no-load write and half-load write
SW1 up / SW1 combination switch (LEHY-2 without energy feedback)
SW2 up / SW2 combination switch (LEHY-2 without energy feedback)
The TCA / MCA switch is on the TCA. Press the SW2 toggle switch up / down to register the top call / bottom call instruction. The switch is under the MCA. Press the SW2 toggle switch up / down to register the up call / down call . (LEHY-2 without energy feedback)
Rotary switch
DNSH downward leveling position adjustment 8 (LEHY-C with energy feedback) (LEHY-2 non-energy feedback)
SHIFT leveling (two-way) position adjustment 8 (LEHY-C with energy feedback) (LEHY-2 non-energy feedback)
MON0 function selection 6/8 (LEHY-C with energy feedback) (LEHY-2 non-energy feedback)
MON1 function selection 0 (LEHY-C with energy feedback
SPDO speed setting factory setting (LEHY-C with energy feedback)
SPD1 Speed setting factory setting (LEHY-C with energy feedback)
WGHO Management Weighing Adjustment 8 (LEHY-C with energy feedback)
WGHG start weighing adjustment 8 (LEHY-C with energy feedback)
ELE.NO ladder setting factory setting (LEHY-C with energy feedback)
SET1 setting function selection 0 (LEHY-2 without energy feedback)
SET0 setting function selection 8 (LEHY-2 without energy feedback)
MON1 display function selection 1 (LEHY-2 without energy feedback)
MON0 display function selection 0 (LEHY-2 without energy feedback)
ELE.NO Elevator setting factory setting (LEHY-2 without energy feedback)